This site uses cookies to improve user experience ok, don't show again read privacy policy x
Languages
Products

LCD UV System Complete Set Ultrarays Purifier Germicidal Lamp

telephone
(+39)0773.52.30.14
fax
(+39)06.233.234.260
e-mail
info@sinergroup.it

RO membranes TFC 1812 - 75GPD (50)

RO membranes TFC 1812 - 75GPD (50)
printask a
question
Ask a question
x
First name

e-mail (*)

Subject

Text (*)

(*) required fields
sendclose
Informations

Code:
090028-02

Weight:
0.25 Kg

Description
RO membranes TFC 1812 - 75GPD (50)
Full description
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA).

These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 200 Gallons per day for use in standard residential membrane housings. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Cysts, Turbidity, Fluoride, Lead, Radium 226/228, Selenium and TDS and are certified D.M. 174/2004 (Italian Ministerial Decree).The membrane remove up to 98% of total dissolved solids (TDS), delivering healthier and safer drinking water.

Features:
* High Rejection & Flow Rate
* Standard dimensions: can be fitted in any RO systems
* Max. inlet Hardness: 25°F. (250ppm)
* Max. Free Chlorine: 0.1 ppm

Type of membrane: Spiral wound

Membrane consists of 3 layers
1. Cross linked fully aromatic polyamide 0.2 µm.
2. Polysulfone 40 µm.
3. Non woven fabric polyester 120 µm.

Spacer: EPDM

Active surface:
1812-50 GPD 0.4 m2
1812-75 GPD 0.4 m2
2012-100 GPD 0.5 m2
2012-150 GPD 0.6 m2
2012-200 GPD 0.8 m2
2012-300 GPD 0.8 m2
3012-300 GPD 1.2 m2
3013-400 GPD 1.4 m2

Specifications Model 090028-01 (1812 - 50 Gpd)
Permeate flow rate (+/-20%) - Gpd: 50 gal./day (190 lt./day)
Minimum salt rejection: 98%
Stabilized salt rejection: 98,50%
Operating pressure test: 80 PSI
TDS feed test: Tap Water (500 ppm)
Water temperature test: 77°F. (25°C.)
Max. operating pressure: 145psi / 0.99 MPa (9,9 Bar)
Max. feed SDI: 5
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 7-7.5
Max. feed water turbidity: 1 NTU

Specifications Model 090028-02 (1812 - 75 Gpd)
Permeate flow rate (+/-20%) - Gpd: 75 gal./day (284 lt./day)
Minimum salt rejection: 97,5%
Stabilized salt rejection: 98,50%
Operating pressure test: 80 PSI
TDS feed test: Tap Water (500 ppm)
Water temperature test: 77°F. (25°C.)
Max. operating pressure: 145psi / 0.99 MPa (9,9 Bar)
Max. feed SDI: 5
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 7-7.5
Max. feed water turbidity: 1 NTU

Specifications Model 090028-03 (2012 - 100 Gpd)
Permeate flow rate (+/-20%) - Gpd: 100 gal./day (379 lt./day)
Minimum salt rejection: 97,5%
Stabilized salt rejection: 98,50%
Operating pressure test: 80 PSI
TDS feed test: Tap Water (500 ppm)
Water temperature test: 77°F. (25°C.)
Max. operating pressure: 145psi / 0.99 MPa (9,9 Bar)
Max. feed SDI: 5
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 7-7.5
Max. feed water turbidity: 1 NTU

Specifications Model 090028-04 (2012 - 150 Gpd)
Permeate flow rate (+/-20%) - Gpd: 150 gal./day (568 lt./day)
Minimum salt rejection: 97,5%
Stabilized salt rejection: 98,50%
Operating pressure test: 80 PSI
TDS feed test: Tap Water (500 ppm)
Water temperature test: 77°F. (25°C.)
Max. operating pressure: 145psi / 0.99 MPa (9,9 Bar)
Max. feed SDI: 5
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 7-7.5
Max. feed water turbidity: 1 NTU

Specifications Model 090028-05 (2012 - 200 Gpd)
Permeate flow rate (+/-20%) - Gpd: 200 gal./day (757 lt./day)
Minimum salt rejection: 97,5%
Stabilized salt rejection: 98,50%
Operating pressure test: 80 PSI
TDS feed test: Tap Water (500 ppm)
Water temperature test: 77°F. (25°C.)
Max. operating pressure: 145psi / 0.99 MPa (9,9 Bar)
Max. feed SDI: 5
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 7-7.5
Max. feed water turbidity: 1 NTU

Specifications Model 090028-06 (2012 - 300 Gpd)
Permeate flow rate (+/-20%) - Gpd: 300 gal./day (1135 lt./day)
Minimum salt rejection: 92%
Stabilized salt rejection: 93%
Operating pressure test: 90 PSI
TDS feed test: Tap Water (500 ppm)
Water temperature test: 77°F. (25°C.)
Max. operating pressure: 145psi / 0.99 MPa (9,9 Bar)
Max. feed SDI: 5
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 7-7.5
Max. feed water turbidity: 1 NTU

Specifications Model 090028-07 (3012 - 300 Gpd)
Permeate flow rate (+/-20%) - Gpd: 300 gal./day(1135 lt./day)
Minimum salt rejection: 95,5%
Stabilized salt rejection: 96,5%
Operating pressure test: 90 PSI
TDS feed test: Tap Water (500 ppm)
Water temperature test: 77°F. (25°C.)
Max. operating pressure: 145psi / 0.99 MPa (9,9 Bar)
Max. feed SDI: 5
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 7-7.5
Max. feed water turbidity: 1 NTU

Specifications Model 090028-08 (3012 - 400 Gpd)
Permeate flow rate (+/-20%) - Gpd: 400 gal./day(1514 lt./day)
Minimum salt rejection: 95,5%
Stabilized salt rejection: 96,5%
Operating pressure test: 90 PSI
TDS feed test: Tap Water (500 ppm)
Water temperature test: 77°F. (25°C.)
Max. operating pressure: 145psi / 0.99 MPa (9,9 Bar)
Max. feed SDI: 5
Chlorine tolerance: <0.1 ppm
Max. operating temperature: 113°F. (45°C.)
Ph range: 7-7.5
Max. feed water turbidity: 1 NTU

TFC Nominal Rejection Characteristics:
Calcium: 93-98%
Sodium: 92-98%
Magnesium: 93-98%
Potassium: 92-96%
Manganese: 96-98%
Iron: 96-98%
Aluminum: 96-98%
Copper: 96-98%
Nickel: 96-98%
Cadmium: 93-97%
Silver: 93-96%
Zinc: 96-98%
Mercury: 94-97%
Hardness Ca & Mg: 93-97%
Radioactivity: 93-97%
Chloride: 92-95%
Ammonium: 80-90%
Bromide: 90-95%
Phosphate: 95-98%
Chromate: 85-95%
Cyanide: 85-95%
Sulfate: 96-98%
Thiosulfate: 96-98%
Silicate: 92-95%
Silica: 80-90%
Nitrate: 90-95%
Boron: 50-70%
Borate: 30-50%
Fluoride: 92-95%
Polyphosphate: 96-98%
Orthophosphate: 96-98%
Chromate: 85-95%
Virus and Bacteria: 99% +
Lead: 95-98%

The rejection percent can vary on the basis of pressure, PH, temperaure and general water quality of the feed water.

WARNING
The reverse osmosis is not a device that makes water drinkable (non-drinkable water into drinkable water) and it works only if it's installed on water complies with the law, municipal potable water or well water if previously made drinkable with adequate and effective systems, preventively studied and personalized for that kind of water. Do not use the system where the water is microbiologically dangerous or of unknown quality without adequate disinfection before and after the system. All systems must be preserved according to the producer instructions. The pollutant parts removed or reduced by this system are not necessarily in your water. Suggest replacement of membrane elements: when flow comes too slow or at least 24 Months.
Customers Login
e-mail
password

Membrane Reverse Osmosis Ionicore Keypra line 300 gpd Water System Filtration High Rejection

www.sinergroup.it Everpure Filters