This site uses cookies to improve user experience ok, don't show again read privacy policy x
Languages
Products

LCD UV System Complete Set Ultrarays Purifier Germicidal Lamp

Sale Agents Login
agent
password
save password
order
other filters

Greenfilter membrane TFC 1812/2012/3012/3013 - 50, 75, 100, 150, 180, 300, 400 GPD
Greenfilter membrane TFC 1812/2012/3012/3013 - 50, 75, 100, 150, 180, 300, 400 GPD
090005
Definition Reverse osmosis process is based on nature and has been used for more than 30 years. These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm. Spacer: EPDM SPECIFICATIONS
Greenfilter encapsulated membranes TFC 50, 75, 100 GPD
Greenfilter encapsulated membranes TFC 50, 75, 100 GPD
090018
High efficiency, disposable encapsulate membranes. Change complete of vessel + membrane for maximum hygiene! These semi-permeable membranes only allow nearly pure water to flow through, by removing excessive salts during the process. Likewise, it also rejects bacteria and micro-organisms, heavy metals, virus. Type of membrane: Spiral wound Membrane consists of 3 layers 1. Cross linked fully aromatic polyamide 0.3 µm. 2. Polysulfone 45 µm . 3. Non woven fabric polyester 100 µm. Spacer: EPDM
Ionicore membrane TFC 2012 - 50, 75, 100, 150, 180 GPD (25)
Ionicore membrane TFC 2012 - 50, 75, 100, 150, 180 GPD (25)
090017
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons per day for use in standard residential membrane housings. All models
details
Permeate flow rate (+/-20%) 50:
50 Gpd (190 lt./day)
Permeate flow rate (+/-20%) 75:
75 Gpd (284 lt./day)
Permeate flow rate (+/-20%) 100:
100 Gpd (379 lt./day)
Permeate flow rate (+/-20%) 150:
150 Gpd (568 lt./day)
Permeate flow rate (+/-20%) 180:
180 Gpd (681 lt./day)
Minimum salt rejection:
96%
Stabilized salt rejection:
98%
Operating pressure test:
65 PSI
TDS feed test:
Tap Water (from 450 to 700 ppm)
Water temperature test:
77°F. (25°C.)
Recovery test:
15%
Max. operating pressure:
125 - 300 PSIG
Max. feed SDI:
5 (15 min)
Max. feed flow rate:
2 gal./min. (7,57 lt./min.)
Chlorine tolerance:
<0.1 ppm
Max. operating temperature:
113°F. (45°C.)
Ph range:
2-11
Max. feed water turbidity:
1 NTU
Membrane style:
Dry
 
Ionicore membrane TFC 3012/3013 - 300, 400 GPD (1)
Ionicore membrane TFC 3012/3013 - 300, 400 GPD (1)
090025
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available in flow rates ranging from 50 to 180 Gallons per day for use in standard residential membrane housings. All models
details
Permeate flow rate (+/-20%) 300:
300 Gpd (1.135 lt./day)
Permeate flow rate (+/-20%) 400:
400 Gpd (1.514 lt./day)
Minimum salt rejection:
97%
Stabilized salt rejection:
97%
Operating pressure test:
100 PSI
TDS feed test:
250 ppm
Water temperature test:
77°F. (25°C.)
Recovery test:
15%
Max. operating pressure:
300 PSIG / 2.06 MPa (20,6 Bar)
Max. feed SDI:
5 (15 min)
Max. feed flow rate:
2 gal./min. (7,57 lt./min.)
Chlorine tolerance:
<0.1 ppm
Max. operating temperature:
113°F. (45°C.)
Ph range:
3-10
Max. feed water turbidity:
1 NTU
Membrane style:
Dry
 
Pentair GRO encapsulated membranes TLC 36, 50, 75 GPD (16)
Pentair GRO encapsulated membranes TLC 36, 50, 75 GPD (16)
090019
GRO (Green RO) membranes are available for 3 types of flow rate: 36, 50 and 75 Gpd. They provide high quality reverse osmosis water while wasting 3 times less water to the drain. Features * TLC Thin Layer Composite membrane * 100% dry membrane maximizing shelf life * Double the recovery over standard RO elements * High rejection stability at high input TDS * Maximal Pressure: 6.90 bar * Maximal Temperature: 49°C * pH: 4-11 * Free Chlorine: 0.1 ppm Benefits * 4 times less water
Pentair membrane TLC 50, 75, 100 GPD (25)
Pentair membrane TLC 50, 75, 100 GPD (25)
090012
TLC™ RESIDENTIAL RO MEMBRANES The best way to assess the overall filtration quality of a RO system is made by measuring the rejection, which is the percentage of total dissolved solids removed from the inlet water. In other words, the higher the rejection, the better the membrane performs. The recovery of a RO system represents the quantity of permeate produced compared with the quantity of concentrate rejected to the drain. The higher the recovery, the lower the rejection is. RO MEMBRANE’S CONSTRUCT
AMI membrane TFC 1812/3012 100, 150, 300 GPD (25)
AMI membrane TFC 1812/3012 100, 150, 300 GPD (25)
090007
AMI Membrane home membrane elements, are among the finest in the industry. With hundreds of thousands of membranes in operation world-wide, we offer these in a large range of both residential and commercial sizes AMI Membranes are Made in the USA in our ISO 9001:2008 Certified Facilities. For the past 30 years AMI Membrane elements have earned the reputation of consistent quality. Recommended Operating Conditions (50, 75, 100, 150gpd) * Maximum operating pressure: 125 psi (8,61bar) * Maximum feed flow
AMI nanofiltration membrane NF 1812 - 150, 200 GPD (25)
AMI nanofiltration membrane NF 1812 - 150, 200 GPD (25)
090008
Nanofiltration Membrane Elements: NF5 What is Nanofiltration? Nanofiltration (NF), in concept and operation, is much the same as reverse osmosis. The key difference is the degree of removal of monovalent ions such as chlorides. Reverse osmosis removes the monovalent ions at 98-99% level at 200psi (13,78bar). Nanofiltration membranes’ removal of monovalent ions varies between 50% to 90% depending on the material and manufacture of the membrane. For this reason, there is a variety of Nanofiltration memb
NF90-2012 nanofiltration membrane - 180 GPD (25)
NF90-2012 nanofiltration membrane - 180 GPD (25)
090006
ALPSPRING offers a full line of RO membrane elements in polyamide composite. The polyamide composite membrane elements display an outsdanding salt rejection of more than 97% , superior product water flow , high thermal and pressure durability , wide tolerance of chlorine and PH. SPECIFICATIONS OF PRODUCT Membrane 180GPD Cod. 090006-01 NF90-2012 NaCl Rejection: >90% ±2% * MgSO4 Rejection >96% * Permeate flow rate: 180GPD Test condition Applied pressure: 150PSI(10,34BAR) * Feed water temperatur
Housings for reverse osmosis membrane 3012 - 300GPD (12)
Housings for reverse osmosis membrane 3012 - 300GPD (12)
090009
Connections * Inlet/Outlet: 1/4"-3/8" * Drain: 1/4"
Housings for reverse osmosis membrane 3012 - 300GPD Greenfilter (1)
Housings for reverse osmosis membrane 3012 - 300GPD Greenfilter (1)
090011
Connections * Inlet: 1/8" * Outlet/Drain: 1/8"
Vessel for reverse osmosis membrane 3012 - 300GPD
Vessel for reverse osmosis membrane 3012 - 300GPD
090021
Connections * Inlet: 1/4" * Outlet/Drain: 1/8"
Vessel for reverse osmosis membrane 3013 - 400GPD
Vessel for reverse osmosis membrane 3013 - 400GPD
090022
Connections * Inlet: 1/4" * Outlet/Drain: 1/8"
Vessel for reverse osmosis membrane 3013 - 400GPD
Vessel for reverse osmosis membrane 3013 - 400GPD
090016
Connections * Inlet: 3/8" * Outlet/Drain: 1/4"
Ionicore membrane TFC LP2521, LP2540, LP4040 Medium pressure
Ionicore membrane TFC LP2521, LP2540, LP4040 Medium pressure
090023
The reverse osmosis (abbreviation: RO, from English Reverse Osmosis) is the process which represents the better water filtration technique, because is not a simply unwanted substances reduction but is able to remove contaminants, harmful and mineral salts at ionic level. The RO membrane element are generally made of polyamide (PA). These R.O. TFC(thin film composite) membranes are available with different flow rates. All models are certified to NSF/ANSI 58 for the reduction of Arsenic ("V" pentavalent),
details
Permeate flow rate (+/-20%) LP2521:
300 gal./giorno (1.135 lt./giorno)
Permeate flow rate (+/-20%) LP2540:
750 gal./giorno (2.839 lt./giorno)
Permeate flow rate (+/-20%) LP4040:
2.500 gal./giorno (9.463 lt./giorno)
Minimum salt rejection:
98%
Stabilized salt rejection:
99%
Operating pressure test:
150 PSI (10,3 Bar)
TDS feed test:
1500 ppm
Water temperature test:
77°F. (25°C.)
Recovery test:
15%
Ph test:
7,5
Max. operating pressure:
600 PSIG / 4.23 MPa (42,3 Bar)
Max. feed SDI:
5 (15 min)
Max. feed flow rate:
16 gal./min. (60,55 lt./min.)
Chlorine tolerance:
<0.1 ppm
Max. operating temperature:
113°F. (45°C.)
Ph range:
3-10
 
Housings 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter
Housings 4" for reverse osmosis membrane 4040x1 - 300psi-EP Greenfilter
090020
Housings 4" for reverse osmosis membrane 4040x1 Cod. 090020-02 Features: * Made of fiber reinforced polyester. * Front connection, permeate the collection at both ends. * Close by blocking half-length AISI-304 easy membrane replacement. * EPDM seals. ABS collector plugs. * Compatible with standard 4 "membranes. * Support brackets included. Connections: * Inlet: 1/2" BSP F. * Outlet/Drain: 3/4" BSP F Technical features: * P
Customers Login
e-mail
password

DMfit quick fit fittings check valves acetalic resin metric inch size food&drink beverage compressed air flow systems

www.sinergroup.it Everpure Filters