Digiflow 8000T Water meters LCD time/volume in liters (50)

Digiflow 8000T Water meters LCD time/volume in liters (50)
printask a
question
Ask a question
x
First name

e-mail (*)

Subject

Text (*)

(*) required fields
sendclose
Informations

Code:
01001205

Weight:
0.2 Kg

Description
Digiflow 8000T Water meters LCD time/volume in liters (50)
click to enlargeclick to enlarge
click on images to enlarge
Full description
The Digiflow 8000T flow meter is of the TIME-FLOW type and measures the flow of water in liters or gallons. The LCD display flashes and sounds an alarm when the filter life limit will be reached.

Features:
Flow rate: 1,8 - 14 L/min (0,5 - 3,7 Gpm)
Temperature: 0 - 40°C (32 - 104°F)
Maximum pressure: 8 Bar (116 psi)
Inlet - Outlet: 3/8" M MNPT
Power supply: 2x AAA batteries

DIGIFLOW 8000T User Instructions
Battery Installation
Slide to open the battery compartment cover and insert 2 AAA batteries. Close the cover.

Setting the Capacity for the Filter
Press and hold DISPLAY for 4-5 seconds, then press RESET and release both buttons. The DigiFlow 6000R will enter into the filter capacity registration procedure.

Press DISPLAY to choose the filter capacity. The sequence is 100-200-300…, 9800-19900-OFF.
Press and hold DISPLAY to speed up the selection sequence.
After selecting the correct capacity, press RESET to save the setting.
Now, press DISPLAY to select after how many days the flow meter should emit an alarm. The sequence is 30-60-90-120...-OFF.

The setup procedure will end and return to the original state if there is no input for 10 seconds.

Operations
The DigiFlow 6000R will turn on automatically when water flows through it. It will automatically turn off after 10 seconds of no water flow.

Press DISPLAY to view the volume of water detected up to that point. Press DISPLAY again to view the remaining capacity of each filter.

End of Capacity Alarm
When each filter reaches a capacity of 0, the Digiflow will produce an audible alarm to alert the user to change the filters. Press RESET to turn off the alarm and reset the filter capacity.

Low Battery Alarm
When the battery power is lower than the normal operating level, a buzzer will emit two beeps to warn of the need to change the batteries. All previously entered settings will be retained in memory in case the battery is completely discharged or removed.

Reset
Press and hold RESET for 8 seconds to reset the flow meter.