Everpure PBS-400
Micro-Pure filtering media 0,5 micron rating density. It removes giardia cysts and cryptosporidium, asbestos fibers, bad taste and odor, chlorine, dirt, rust, invisible particles, mold and algae. It also reduces oxidized iron, manganese and sulphate.

* Ideal for drinking and cooking in maximum safety.
* Improve taste of beverages, sparkling water and post-mix systems.
* Protect from clogging, corrosion and wear.
* No electrical connection required.
* Vertical installation.
* The rapid filter is easy to install and replace without use of special tools.

Features:
* Chlorine reduction
* Reduction of cysts
* Reduction of particulate in suspension

• Technology: Precoat, activated carbon (PAC), Micro-Pure
• Micron rating: 0,5 micron
• Service life: 3.000 gallons (11.356 Liters)
** Capacity varies according to:
* Inlet water quality
* Required flow rate
* Inlet water pressure
* Filter use (continuous or intermittent)

• Service flow rate: 8,3 l./Min. (2,2 gpm)
• Temperature: 35 - 100°F (2-38°C)
• Pressure: 10 - 125 psi (0.7 - 8.6 bar), non-shock.
• Cartridge dimensions HxD (mm.): PBS-400 510X130 (mm.) – 20"x5" (In.)
(Leave a vertical space of about 7 cm under filter to allow replacement).
• Activation: it is advisable to run water through filter at maximum pressure and full flow rate, for at least 5 minutes to allow air purging and flushing of cartridge.
• Cartridges change: When capacity is reached, or when flow comes too slow (precipitates under 0.7bar/10psi), every 6 months but at least annually.

Do not use with microbiologically unsafe or unknown quality water without disinfecting first. Cysts reduction certified systems can be used with disinfected water that may contain filterable cysts. All systems must be mantained according to the producer instructions.
Nota bene: The removed or reduced contaminant agent may not necessarily be in your water.