Digiflow 8100T Water meters LCD time/volume in liters (50)

Digiflow 8100T Water meters LCD time/volume in liters (50)
printask a
question
Ask a question
x
First name

e-mail (*)

Subject

Text (*)

(*) required fields
sendclose
Informations

Code:
01001208

Weight:
0.15 Kg

Description
Digiflow 8100T Water meters LCD time/volume in liters (50)
click to enlargeclick to enlarge
click on images to enlarge
Full description
Flow meter with external turbine type Time-Metered measures water flow in liters or gallons.
* IN - OUT: 1/4" BSP male

Features:
- Flow Rate : 0,6 - 8 L/min (0,16 - 2,11 Gpm)
- Temperature : 0 - 80°C (32 - 176°F)
- Max pressure: 8 bar (116 psi)
- Filter capacity life monitor (from 500 to 99500 liters);
- Filter elapse time monitor (from 30 to 720 days);
- Flow rate display (0,8 -8,0 lpm);
- Near end of filter life alert;
- End of filter life alert;
- Low battery power alert;
- Automatic data memorized when battery power is off.

Application:
- Undercounter water treatment system;
- Commercial water treatment system;
- Water dispenser.

INSTALLING BATTERY
Slide off the cover case of the battery room, and put into 2AA batteries.Then slide the cover case back.

SETTING CAPACITY AND TIMING
Keep pressing display button, then press reset button and release both of the buttons. The DigliFlow 8100T will go into setting procedure. The digit will flash to notice you that the setting procedure is on.

CONNECTING FITTING
The specification of the DigiFlow8100T connectors is 1/4" BSP male.

SETTING CAPACITY
Press display button to choose the capacity. The sequence is -500-1000...99500-OFF. Then press reset button to save the capacity. Then go into Timing setting.

SET TIMING
Press Display button to choose the Timing. The sequence is 0-30-60-90...690-720-0-30OFF. Then press reset to save the Timing. The setting procedure is completed. *The capacity mode will be disabled when you choose OFF. **The setting procedure will be terminated, and go back to the original status if there is no input for 10 seconds.

OPERATING
The DigiFlow 8100T will be automatically on when there is any water flowing through the sensor. It will be automatically off wen there is no water flowing for 10 seconds.

DISPLAY BUTTON:
Press display button is to display the status of the three modes of the DigiFlow 8100T. Capacity mode: showing the capacity left. Timing mode; showing the timing left. Flow rate mode: showing the current flow rate. The sequence is Flow-rate - Timing Capacity...

RESET BUTTON:
Press reset button is to reset the setting to be the last setting.

ALARM - Noticing Alarm
When Capacity is lower than 100 gallons or timing is lower than 7 days, the buzzer will beep once and the digit will beep once and the digit will flash to notice you to prepare changing the filter cartridge when there is any water flowing through DigiFlow 8100T or press the display button.

Warning Alarm
When Capacity reaches 0 gallon or Timing reaches 0 day, the buzzer will beep twice and the digit will flash to notice you to change the filter cartridge when there is any water flowing through Digiflow 8100T or press the display button.

Low Battery Power Alarm
When the battery power lower than normal working level, the buzzer will beep twice to notice you to change the battery. The data will be kept in memory when the battery power is run out or battery is removed.